Subscribe to: Heart Care Info RSS Feed  

Heart Care Info - Heart Disease Prevention & Treatment

  Heart health     Cardiopathy     Heart study     Cardiology      Email A Friend  
Heart disease
Heart attack
Heart failure
Heart surgery
Heart Care Info
Heart transplantation
Bypass surgery
Cardiovascular disease
Arrhythmia
Atherosclerosis
Heart rate
Cardiac arrest
Cardiac death
Cardiac surgery
Cardiovascular system
Cardiomyopathy
Endocarditis
Cardiomegaly
Myocarditis


High Dose Daptomycin for Cardiac Implantable Electronic Device Related Infective Endocarditis, endocarditis

High-Dose Daptomycin for Cardiac Implantable Electronic Device–Related Infective Endocarditis


Heart Care Guide - http://www.heartcareguide.net

E Durante-Mangoni, R Casillo... - Clinical Infectious ..., 2012 - Background. Cardiac implantable electronic device (CIED)related endocarditis is a growing challenge because of increasing incidence and significant mortality. Current treatment is based on complete hardware removal coupled with long-term administration ...

Background. Cardiac implantable electronic device (CIED)–related endocarditis is a growing challenge because of increasing incidence and significant mortality. Current treatment is based on complete hardware removal coupled with long-term administration of effective and safe antimicrobials. Daptomycin at the dose of 6 mg/kg/day has been found to be effective in staphylococcal endocarditis, but limited data exist on CIED endocarditis. Moreover, whether higher doses could be more effective but equally safe in this setting is currently unknown.

Results. Patients were mostly elderly and male, with large lead vegetations and severe comorbidities. Pathogens were Staphylococcus epidermidis (56%), Staphylococcus aureus (28%), and other coagulase-negative staphylococci (16%). Only 4 patients (16%) had a normal pretreatment renal function. The median daptomycin daily dose was 8.3 mg/kg (range, 6.4–10.7). Daptomycin was administered for a median of 20 days (range, 8–52). Percutaneous lead extraction was performed in 88% of patients. Two patients (8%) failed to clear bacteremia. The overall clinical success of treatment was 80%, whereas a complete microbiological success was observed in 92% of patients. Creatine phosphokinase values were monitored and increased above normal in 5 cases (20%). No serious adverse event related to high-dose daptomycin was observed and no patient required discontinuation because of muscle toxicity.

More Details:

High-Dose Daptomycin for Cardiac Implantable Electronic Device–Related Infective Endocarditis
Cardiovascular health
Cardiovascular surgery
Coronary artery disease
Coronary artery bypass graft

Subscribe to Heart Care Info by Email
Your email address:

Heart Care Guide
Life & Health Center
Find Doctor in Town
Health Care Jobs
Heart disease treatment